Forms and Interactions for Automated Equipment Yield Rates

Daily yield and market report data for automated equipment is sourced from local device operation logs, industrial IoT collection nodes, and upstream

What this category of data looks like

Daily yield and market report data for automated equipment is sourced from local device operation logs, industrial IoT collection nodes, and upstream raw material market APIs. A single daily report document is generated at a fixed time each day. The document structure splits entries by device. Each entry includes a unique device identifier, runtime duration, single-day revenue value, cumulative revenue value, associated market index, and abnormal operation flag. Field units are as follows: runtime duration is measured in hours, revenue values are measured in yuan, and market indexes are dimensionless numbers.

Constraints imposed on forms and interactions workflows

Daily fixed updates to report data require forms to support date range filtering and querying. Submissions are only allowed during the fixed window after daily data is generated, to prevent invalid edits. For multi-device cluster management scenarios, forms must include a bulk upload entry and per-batch quantity limits, to support bulk import of device data. Multiple data sources create data validation requirements, so forms must include field format validation rules to ensure core fields such as device identifiers and revenue values comply with specifications. The abnormal operation flag field must link to a note entry, to enable quick tracing and handling of abnormal data. Additionally, forms must support using user-input device numbers and dates as core parameters to generate targeted question-and-answer content.

Configuration settings

Configuration ItemRecommended ValueRationale
recallTopKTop 6–10 entriesThe daily report data for automated equipment has a structured format, and a small number of recalls can cover core device and revenue information
similarityThreshold0.72–0.80Accurate matching of device numbers and date parameters is required to avoid recalling irrelevant historical daily report data
PARSE_FILE_TIMEOUT_SECONDS300–420 secondsA single daily report document contains data for multiple devices, so parsing takes longer than plain text files
UPLOAD_FILE_MAX_SIZE500 MBBulk imported device daily report Excel files typically do not exceed this threshold
formFieldRequiredDevice number, date, single-day revenue valueMissing core fields will prevent normal association and analysis of daily report data
formSubmitTimeWindowDaily 17:00–19:00Aligns with the fixed window for daily production data aggregation in the industry, to prevent invalid submissions

The parameter values provided on this page are common recommended starting points for configuration setup. Actual values are affected by material format, data volume, and business rules. Specific issues require case-by-case analysis. Testing on dedicated samples is recommended before finalizing values.

Three common configuration mistakes

  • Phenomenon: The question-and-answer results generated after form submission do not link to the user-input device number and date, and only return general revenue data. Cause: The formFieldRequired configuration is not set to enforce retrieval of device number and date parameters, leading to missing subsequent association logic.
  • Phenomenon: A 413 Request Entity Too Large error appears when uploading a device daily report Excel file, while text conversation functions operate normally. For the domestic SaaS version V4.8.17 free tier, this error may also relate to the platform's default file upload limits not being adapted. Cause: The UPLOAD_FILE_MAX_SIZE configuration item is not adjusted, so the uploaded file exceeds the platform's default limit.
  • Phenomenon: When configuring a knowledge base, locally deployed inference models cannot be selected, and only cloud model options are displayed in the interface. Cause: The access address and port of the local model are not correctly configured in config.json, so the platform cannot recognize them.

How to confirm configuration is complete

  • Enter the form configuration page, check that core fields are marked as required, and confirm that the formFieldRequired configuration item includes the device number, date, and revenue value fields.
  • Upload a test device daily report file, review the upload progress and parsing results, and confirm that parsing time does not exceed the PARSE_FILE_TIMEOUT_SECONDS configuration value.
  • Initiate a query that includes a device number and date, verify that the recalled results match the specified device's single-day revenue data, and confirm that the recallTopK and similarityThreshold configurations meet requirements.
  • Attempt to submit the form outside the configured submission window, confirm that the system blocks invalid submissions, and verify that the formSubmitTimeWindow configuration takes effect.

Question material comes from public community discussions. Configuration values are common starting points and should be measured against your own samples. Verified on 2026-09-14.