Public Financial Expenditure Performance Evaluation Service Inquiry and Response: Deployment and Upgrade

Public Financial Expenditure Performance Evaluation Service Inquiry and Response: Deployment and Upgrade

What the data for this category looks like

This category’s data covers the full lifecycle of fiscal project performance. Daily documents include performance target forms, self-assessment forms, performance evaluation reports, supporting material lists, and rectification reports. Data sources include the unified budget management system, project declaration materials, fund payment data, business system ledgers, and satisfaction surveys. The update frequency is annual. Data fields link project identifiers, performance indicators, fund usage records, and supporting material numbers, to match performance targets with actual expenditure outcomes.

What constraints these characteristics impose during deployment and upgrade

Configure multi-source data connection and adaptation logic during deployment to avoid data silos, as data sources are scattered across multiple business systems. Use a batch offline synchronization configuration mode, since the annual update frequency makes high-frequency incremental synchronization unnecessary. Support multi-format parsing and field mapping during deployment to handle diverse document types, ensuring accurate association of performance indicators, fund records, and supporting materials. Optimize retrieval matching association rules during upgrades to improve data verification efficiency, to meet verification requirements for core time-consuming links.

How to set the configurations

Reference only; verify against the target FastGPT release and deployment documentation.

Configuration ItemRecommended SettingRationale
DB_MAX_LINK10–15 connectionsAdapts to annual batch synchronization database connection requirements, avoiding connection exhaustion
MONGODB_URIdedicated database instance storing performance documents and evaluation dataIsolates business data from other system data, ensuring the security of performance data
REDIS_URLlocal cache instance, with cache validity set to 86400 secondsCaches annually updated performance indicator and fund association data, reducing repeated queries
STORAGE_S3_ENDPOINTenterprise internal object storage service addressStores large-volume documents such as supporting materials, adapting to multi-format file upload and retrieval
ROOT_KEYdedicated key generated in accordance with internal permission control rulesRestricts unauthorized personnel from modifying performance evaluation configurations
FILE_TOKEN_KEY16-digit random string, with token validity set to 3600 secondsGenerates temporary access tokens for supporting materials, avoiding public exposure of storage paths

Three common configuration errors

  • Request timeout errors occur during conversations. Cause: The DB_MAX_LINK configuration was not adjusted for annual batch data synchronization, leading to database connection exhaustion and failure to respond to inquiry requests in a timely manner.
  • Supporting material search returns no results. Cause: STORAGE_S3_ENDPOINT was not configured correctly, failing to associate stored supporting file paths, resulting in missing corresponding materials.
  • The system cannot call data interfaces from the unified budget management system. Cause: Permission verification was not configured via ROOT_KEY, leading to cross-system connection being blocked and failure to obtain fund payment and performance target association data.

How to confirm the configuration is complete

  • Run the annual batch synchronization script, verify that the database connection count does not exceed the configured limit.
  • Upload a performance self-assessment form document, confirm that it can be associated with storage and indexed via the storage configuration.
  • Initiate a performance inquiry test request, confirm that the response meets internal business requirements.
  • Attempt to access the system configuration page using an unauthorized key, verify that permission control takes effect.

The values provided are common starting points and should be measured against the reader's own samples.

Question material comes from public community discussions. Configuration values are common starting points and should be measured against your own samples. Verified on 2026-09-28.