What the data for this category looks like
The core data for this category comes from the food safety sampling and monitoring system, the State Administration for Market Regulation sampling results query system, laboratory LIMS, and enterprise account books. The update frequency is monthly. Documents handled daily include sampling plans, sampling slips, inspection reports, non-compliant food verification and disposal reports, and risk control notices. The fields of each document vary significantly: sampling slips include fields such as sample number, sampling location, and sampling quantity; inspection reports include content such as test items, test results, and judgment basis; non-compliant disposal reports include information such as recall measures and rectification status.
What constraints these characteristics impose on the deployment and upgrade link
Monthly updated data sources require incremental synchronization mechanisms to avoid excessive system resource consumption from full synchronization. Multi-source, multi-structure documents need adapted parsing and template rules to ensure accurate field extraction. The sensitivity of regulatory data requires strict access controls to prevent unauthorized access to non-compliant test information. Large-volume documents such as inspection reports need large-capacity storage configurations to avoid file storage failures. Additionally, some documents must be submitted in PDF format, which relies on dedicated parsing tools and imposes hardware resource requirements on the deployment environment. Multi-role access needs from entities such as grassroots supervision institutes and testing institutions must also be covered in the configuration.
How to set the configurations
Reference only; verify against the target FastGPT release and deployment documentation.
| Configuration Item | Recommended Approach | Rationale |
|---|---|---|
FILE_TOKEN_KEY | Randomly generated 32-character encrypted string | Generates authentication credentials for sampling document sharing links, preventing unauthorized access to sensitive test data |
REDIS_URL | redis://default:your_password@redis-host:6379/1 | Caches temporary verification data for monthly sampling plans and sampling slips, reducing the frequency of repeated queries to external systems |
STORAGE_S3_ENDPOINT | Intranet access address of private object storage | Stores large-volume documents such as inspection reports and non-compliant food verification and disposal reports, adapting to batch storage needs |
DB_MAX_LINK | 500–800 entries | Limits the maximum number of data entries synchronized from the food safety sampling and monitoring system per single sync, avoiding sync timeouts |
FE_DOMAIN | Frontend access domain name of the deployment environment | Used to splice authenticated document sharing links, complying with access control specifications for regulatory data |
Three common errors
- Phenomenon: Sampling document sharing links cannot be accessed normally, returning a 403 status code. Cause:
FILE_TOKEN_KEYis not configured, or the secret key does not match the frontend domain name, resulting in authentication failure. - Phenomenon: Parsing failure errors occur when importing inspection report PDFs. Cause: The marker Docker container is not properly built, or local GPU video memory is insufficient to process high-resolution inspection report files.
- Phenomenon: Monthly sampling data synchronization tasks time out and are interrupted. Cause: The value of
DB_MAX_LINKis not limited, and the single synchronization data volume exceeds the system load threshold.
How to confirm the configuration is valid
- Access the generated sampling document sharing link, verify that authentication is required, and only authorized users can view the corresponding documents.
- Import a standard-format inspection report PDF, confirm that there is no format disorder or missing key fields after parsing.
- Trigger a monthly sampling data synchronization task, check the system log to confirm that the task executes without timeouts or data truncation issues.
- Check whether corresponding files such as inspection reports and verification and disposal reports are generated in the private storage bucket, confirming that the storage configuration takes effect.
The values provided are common starting points and should be measured against the reader's own samples.
Question material comes from public community discussions. Configuration values are common starting points and should be measured against your own samples. Verified on 2026-09-28.