What the Data for This Category Looks Like
The data for this category primarily comes from project document libraries, configuration lists, meeting minutes, and test reports. Updates occur after each project phase delivery or when the overall project concludes. Daily produced documents include completion documents, configuration manuals, training records, and acceptance certificates. Core fields include project unique identifier, document version number, signature verification status, and associated external system ID. The size of a single document is usually under 100 MB. Some batch handover archive packages can reach up to 1000 MB.
Constraints Imposed on HTTP Interfaces and External Systems by These Characteristics
The non-real-time nature of data updates requires interfaces to support scheduled batch-triggered handovers, without the need for high-frequency real-time calls. Document fields include signature verification status and associated external system ID. This requires HTTP interface request bodies to carry corresponding verification parameters, and response bodies to return verification results. The wide range of single document sizes requires interfaces to support custom request timeouts, to adapt to both fast responses for small files and long wait times for large archive packages. Differences in data formats from multiple sources require the variables configuration to adapt to field mapping rules for different data sources, to prevent handover failures caused by format incompatibility.
How to Configure Settings
The following configuration items are adapted for FastGPT v4.17.0:
| Configuration Item | Recommended Setting | Rationale |
|---|---|---|
Authorization | Carry a project-specific token, set validity period to 7 days | Adapt to the batch operation cycle of project document handovers, avoid frequent token refreshes |
variables | Configure project number and document category tags as fixed variables | Uniformly map core fields from documents of different sources, reduce format conversion costs |
responseData | Only return three fields: signature verification status, handover progress, and failure details | Streamline response content, reduce network transmission time, adapt to batch handover scenarios |
| Request timeout duration | 600–1200 seconds | Cover transmission and verification time for 1000 MB archive packages, prevent mid-transfer interruptions |
| Batch handover limit | 20 documents per single call | Balance interface load and handover efficiency, adapt to document quantity constraints per batch |
Three Common Misconfigurations
- The interface returns a
401 Unauthorizedstatus code, and the handover task fails directly. This occurs when theAuthorizationparameter is not configured correctly, an expired token is used, or permissions for the corresponding project are not bound. - Some document version information is empty after batch handover, causing subsequent acceptance steps to fail. This occurs when the document version field is not mapped via the
variablesconfiguration, so the interface cannot extract the corresponding metadata. - The interface returns a 504 Gateway Timeout when handing over more than 20 documents in a single request. This occurs when a reasonable batch handover limit is not set, exceeding the interface's carrying capacity and causing a timeout.
How to Verify Successful Configuration
- Call the test interface, check that the response body contains only the specified fields configured in
responseData, with no extra unrelated content. - Configure a scheduled trigger task, verify that the interface can automatically send handover requests after a project phase ends, with no abnormal interruptions.
- Adjust the batch handover quantity, confirm that the interface load stays within a reasonable range, with no obvious timeouts or errors.
- Upload a test document with a signature, verify that the interface can correctly return the signature verification status field.
The values provided are common starting points and should be measured against the reader's own samples.
Question material comes from public community discussions. Configuration values are common starting points and should be measured against your own samples. Verified on 2026-10-19.