Cross-Review of Technical Documentation for Electroplating and Chemical Surface Treatment: Tool Calling and Plugins

This category’s data is primarily sourced from customer surface treatment specifications, bath test results, rectifier operation logs, online water

Data for This Category

This category’s data is primarily sourced from customer surface treatment specifications, bath test results, rectifier operation logs, online water quality monitoring records, and hazardous waste management ledgers. Daily generated documents include bath analysis records, process parameter cards, fixture usage logs, film thickness and adhesion reports, hazardous waste ledgers, and wastewater monitoring records. Data updates occur per bath run, per shift, or per fixed monitoring requirements. Document fields include bath concentration, operating temperature, current parameters, film thickness values, discharge metrics, and more, with standard units including g/L, ℃, A, μm, and mg/L.

Constraints Imposed on Tool Calling and Plugins

This category’s data has high update frequency, diverse types, and fields with specialized units, creating multiple constraints for tool calling and plugins. High-frequency updated bath and water quality data requires tools to support real-time retrieval of the latest online monitoring and test data, avoiding reliance on expired offline documents. Differences in fields across document types (such as the μm unit for film thickness, g/L unit for bath concentration) requires plugins to adapt to format parsing rules for different documents, ensuring accurate parameter matching. Cross-document association requirements (such as the link between bath composition and wastewater discharge) requires tool calling to support information integration across data sources, while also verifying parameter legitimacy to mitigate mass production risks.

Configuration Settings

Configuration ItemRecommended SettingRationale for This Setting
Workflow/API tool selectionautoAdapt to the cross-review needs of multiple document types in this category, automatically matching corresponding tools
Workflow/API function-call configurationEnabled and limited to bath analysis and water quality monitoring toolsFocus on core business data of this category, avoiding unrelated tool calls
Multimodal system plugin enablementEnabled and bound to document parsing toolsUsed to identify documents such as film thickness reports with charts and process parameter cards
MCP function enablementEnabled and configured with trigger condition set to after document upload completionAutomatically trigger cross-document compliance and parameter verification
File upload recognition interface configurationSupports xlsx and pdf formats, single file maximum size 800 MBCovers commonly used report and document types in this category
Tool call timeout setting600 secondsAdapts to FastGPT v4.17.0 version tool call rules, matches the parsing and data pulling time required for complex documents in this category
Number of returns per single tool callTop 5 entriesMatches the number of core documents for a single production batch

Three Common Misconfigurations

  • An aiPointsNotEnough error is returned through interface calls. The cause is that category-specific bath analysis and water quality monitoring tools are not limited during tool calling, triggering unrelated data requests that exceed quota limits.
  • xlsx format bath analysis records cannot be processed in AI conversations. The cause is that parsing rules adapted to spreadsheet documents are not configured, or the file size exceeds the interface-set maximum limit.
  • Multimodal system plugins fail to correctly recognize parameters in film thickness reports. The cause is that a parsing tool for documents with charts is not bound, or the multimodal plugin enablement switch is not activated.

How to Verify Proper Configuration

  • Upload an xlsx format bath analysis record for this category, and check if the tool automatically calls bath analysis tools.
  • Trigger a cross-document review process, and confirm if the corresponding batch’s hazardous waste ledger and wastewater monitoring records are automatically pulled.
  • View the tool call log, and confirm that the number of returned results matches the configured single-call limit.
  • Test uploading a multimodal document, and confirm if the plugin can recognize film thickness values and chart data in the report.

The values provided here are common starting points and should be evaluated against the reader's own samples.