Business Process Guidance for Civil Aviation Airports: Deployment and Upgrade

Business Process Guidance for Civil Aviation Airports: Deployment and Upgrade

Reference only; verify against the target FastGPT release and deployment documentation.

What the Data for This Use Case Looks Like

Data sources for civil aviation airport business process guidance include flight scheduling systems, check-in counter terminals, security gate logs, and interaction data from public service terminals in airport terminals.

Data updates are triggered by business nodes. Real-time push updates occur when flight information changes. Daily business data is synchronized once per hour.

Data uses a structured format, including fields such as flight number, takeoff and landing time, terminal number, counter number, security channel number, and guidance step sequence. Flight number uses a string format. Takeoff and landing time uses ISO standard time format. Terminal number uses a two-digit numeric code. Guidance steps use an ordered numeric sequence.

Constraints Imposed by These Characteristics on Deployment and Upgrade

Real-time flight data requires database connections configured to support high-concurrency writes. Do not use read replicas as primary storage nodes.

Structured fixed fields require unified mapping rules defined in advance. Arbitrary modification of field mappings during upgrades will cause guidance step matching errors.

Multi-system integration requires a pre-configured data format validation link. Deploy validation logic during deployment to prevent dirty data from entering the knowledge base.

The airport internal network deployment scenario requires all configurations to adapt to internal network access rules. Do not rely on external network resources. Retain compatibility with internal network caching policies during upgrades.

Configuration Settings

Configuration ItemRecommended ValueRationale
DB_MAX_LINK100–150 connectionsAdapts to concurrent business requests from multiple airport terminals, prevents database connection exhaustion
MONGODB_URIIncludes the read replica address of the airport business database, adds read-write separation parametersEnsures read/write performance of real-time flight data, avoids excessive pressure on the primary database
REDIS_URLConfigured as a local cache node, set expiration time to 300 secondsCaches guidance data for popular flights, reduces database query frequency
FE_DOMAINAirport terminal internal network domain nameLimits front-end access scope, adapts to the airport internal network deployment scenario
STORAGE_S3_ENDPOINTInternal network address of the airport’s internal object storageStores multimedia materials for guidance processes, complies with internal network data security requirements
ROOT_KEYGenerated according to the airport’s internal network permission rulesRestricts background management access permissions, prevents unauthorized configuration modifications

Three Common Misconfigurations

  • Front-end pages load indefinitely with a spinning indicator, and the guidance interface fails to display. The cause is incorrect configuration of the FE_DOMAIN parameter, preventing front-end resources from loading via the internal network domain, or the cache node pointed to by REDIS_URL failed to start normally.
  • Model connection tests report errors, and locally deployed models cannot be called. The cause is that internal network model access permissions were not enabled in the configuration, or MONGODB_URI did not correctly point to the local data cache link, causing the model call chain to break.
  • Guidance step matching errors occur, and outdated flight information is displayed. The cause is that the original data mapping rules were not retained during the upgrade, leading the new configuration to overwrite the field correspondence, allowing dirty data to enter the knowledge base.

How to Verify Successful Configuration

  • Access the internal network address specified by FE_DOMAIN. Verify that the front-end page loads normally with no spinning indicator or error prompts.
  • Run a model connection test. Verify that locally deployed models can be called, and return expected guidance step results.
  • Simulate a flight change operation. Verify that the system completes guidance data refresh within the configured update cycle, with no delays or data loss.
  • Check database connection logs. Verify that the concurrent connection count for DB_MAX_LINK does not exceed the set threshold, and no connection timeout errors occur.

The values provided are common starting points and should be validated against local deployment samples.

Question material comes from public community discussions. Configuration values are common starting points and should be measured against your own samples. Verified on 2026-09-28.